BFCBM - X-4609 WHITE PAINT
- MSDS: BFCBM
- Manufacturer: SENTRY PAINT AND CHEMICAL CO DARBY PA 19023
- Product Name: X-4609 WHITE PAINT
- National Stock Number: 8010-00-515-1596
Product Identification
Product ID:X-4609 WHITE PAINT
MSDS Date:01/01/1987
FSC:8010
NIIN:00-515-1596
MSDS Number: BFCBM
Responsible Party
DARBY, PA 19023
US
Cage: GO855
Contractor
Cage: 34346
Ingredients
ALKYD
Fraction By Weight: 33.0%
NAPHTHA (PETROLEUM SPIRITS OR BENZIN)
CAS: 8030-30-6
RTECS: SE7555000
Fraction By Weight: 42.0%
OSHA PEL 100 PPM
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 25%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
Hazards
Effects of Overexposure:DIZZINESS, HEADACHE AND NAUSEA
First Aid
First Aid:REMOVE TO FRESH AIR.GIVE ARTIFICIAL RESPIRATION IF BREATHING
STOPS.
Fire Fighting
Flash Point:108F TCC
Lower Limits:0.9
Upper Limits:6.0
Extinguishing Media:FOAM,CO2,DRY CHEMICAL
Fire Fighting Procedures:USE EQUIPMENT SUPPLIED AIR SUPPLY FOR ENCLOSED
AREAS.
Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID
Accidental Release
Spill Release Procedures:CLEAN UP AS ANY FLAMMABLE LIQUID. AVOID
SPARKS, USE DRY ABSORBENT IF POSSIBLE
Handling
Handling and Storage Precautions:AVOID OPEN FLAME AND HIGH TEMPERATURE
Exposure Controls
Respiratory Protection:CARTRIDGE TYPE RESPIRATOR
Ventilation:LOCAL EXHAUST
Supplemental Safety and Health
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:317-388F
Vapor Pres:5
Vapor Density:4.8
Spec Gravity:1.1
Evaporation Rate & Reference:SLOWER THAN NBUACT
Solubility in Water:NEG
Appearance and Odor:WHITE LIQUID
Percent Volatiles by Volume:55.0
Stability
Stability Indicator/Materials to Avoid:YES
Disposal
Waste Disposal Methods:ABSORBING MATERIAL CAN BE INCINERATED
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.